The complete guide to drawing an electrical plan in RoomSketch3D
One page for the whole job: which symbols exist, how outlets, switches, combinations and lights go on the plan, how to lock a device's distance along the wall, how stacked devices show their heights, how to draw, route and colour circuit lines, how to label breakers, the Electrical plan view, what prints in each export, how to make a separate plan for each trade, the cable list with run lengths, and the placement rules (US code and German DIN) to check your plan against.
An electrical plan is the drawing an electrician quotes and wires from: where every outlet and switch sits on the walls, where the lights, fans and detectors go on the ceiling, which switch runs which light, and which outlets share a breaker. RoomSketch3D draws all of that on top of your floor plan with standard symbols, and prints it as a clean sheet with a symbol legend and a circuit list.
This guide is the reference for all of it. It runs in the order you would build a plan: what the plan contains, the symbols and how they scale as you zoom, putting devices on walls and in rooms, the settings of each device, locking a device's distance along the wall, outlet and switch combinations (side by side, stacked with the height of each device printed on the plan, reordering), naming, circuit lines (drawing, finishing, routing along the walls, editing, colours and line styles), the settings card, right-click shortcuts, the Electrical plan view, the legend and circuit table, exports, separate plans per trade (electrician, symbols only, furniture), the cable list with the length of every run, the 3D view, the rules to check your layout against (US code and German DIN 18015-3), shortcuts, and what the app can't do yet with the workaround for each.
Quick answer: open Symbols (the tab after Indoor and Outdoor, or the Symbols pill on a phone), tap an outlet or switch tile, tap +Add and tap a wall. Drop lights with +Add and drag them into place. Drag one outlet or switch onto another to make a combination. Tap Circuit line, tap the devices in wiring order (tap empty space to bend the line along a wall), then press Enter, double-click, or click the last symbol again. Then Export / Print / Share → PNG/JPG/PDF or Print, under Views untick Floor plan and tick Electrical plan (that adds the Symbol legend & circuit table and leaves out the furniture), keep Labels ticked, and export.
Shorter task pages: Draw an electrical plan (placing and naming devices), Outlet and switch combinations, Circuit lines, Upload your own symbols and the floor plan symbols reference.
What you'll need
- •A floor plan with walls (one room is enough; a template works well)
- •A computer, tablet or phone: everything here works on all three, and the phone layout differences are noted
In this guide
- 1
What an electrical plan in RoomSketch3D contains
A finished plan has four layers of information, all drawn over the walls, doors and windows you already have:
Layer What it is Where it comes from Wall devices Outlets (sockets) and switches, alone or in combinations Symbols panel, tap a wall Room symbols Ceiling, recessed, pendant and track lights, fans, detectors, data and phone jacks, Wi-Fi, cameras, panel, junction box, plumbing and HVAC marks Symbols panel, +Add, then drag Circuit lines Solid or dashed runs from device to device, with a name such as Breaker 7 Circuit line tool in the Symbols panel Names Breaker numbers or descriptions beside devices and on each circuit The name box of any device or line The example on this page is the Medium 2-Bedroom Apartment template with an electrical plan added in the living room and kitchen: a range outlet (R), a GFCI outlet over the counter, a two-gang switch by the front door (single + dimmer named Living lights), a switch with an outlet below it on the kitchen wall, a double outlet behind the TV, pendants over the island, recessed lights, a ceiling light and a smoke detector. Three circuits: Breaker 7 (blue, dashed) runs the outlets along the walls, Breaker 3 (red, solid) runs the dimmer to the living-room light around the corner, and Breaker 5 (green, dashed) runs the kitchen switch to the recessed lights and pendants. The kitchen switch and its outlet are stacked, so their heights (46" and 12") are printed beside them.
The example plan: Breaker 7 (blue) along the outlets, Breaker 3 (red, solid) to the living-room light, Breaker 5 (green) to the kitchen lights. - 2
Every electrical symbol you can place
The Symbols panel holds 69 built-in symbols in three packs. Tabs at the top pick All, US or Europe; it opens on US if you work in feet and inches and on Europe if you work in metres, then remembers your choice. Search filters everything (try gfci, dimmer, schuko, ethernet). Your own uploads sit under My Library at the top.
Pack Outlets / sockets Switches US (27) Single, Duplex, Quad, GFCI, 20A, 240V, Range, Dryer, Weatherproof, Switched, USB, Tamper-Resistant, Isolated Ground, AFCI, Floor Outlet Single, Double, 3-Way, 4-Way, Dimmer, Smart, Pilot Light, Key, Timer, Occupancy Sensor, Weatherproof, Low Voltage Europe (14) Earthed, Unearthed, Double, Triple, Switched, Outdoor IP44, USB, 400V 3-Phase One-Way, 2-Gang, Two-Way, Intermediate, Dimmer (EU), Push Button Shared (28), the same in every region: Ceiling, Recessed, Wall, Pendant, Track and Under-Cabinet lights, Ceiling Fan, Electrical Panel, Smoke Detector, CO Detector, Smoke/CO Detector, Doorbell, Motion Sensor, Junction Box; plumbing (Shut-off Valve, Floor Drain, Hose Bib, Water Heater); HVAC (Thermostat, Supply Vent, Return Vent); telecom (Phone Jack, Data Jack, Wi-Fi Access Point); CCTV Camera; and North Arrow, Marker Dot, Callout Circle.
Each outlet and switch kind draws its own plan mark, with a short tag where the trade uses one: GFCI, 20A, R (range), D (dryer outlet; on a switch, dimmer), WP, USB, TR, IG, AFCI, 3 and 4 (3-way, 4-way), P (pilot light), K (key), T (timer), OS (occupancy), LV (low voltage), a wireless mark for smart switches, and on European sockets 2, 3, IP44 and 400V. A tile also shows the real plate size (for example 2.75 × 4.5 in for a duplex outlet).
The Furnish catalog (Indoor → Fixtures) also has six 3D wall devices: Light Switch (3D), Double Light Switch (3D), Dimmer Switch (3D), Duplex Outlet (3D), GFCI Outlet (3D) and USB + Outlet (3D). They place the same way and become the same kind of wall device; the Symbols panel simply has far more kinds. Anything missing can be drawn as a transparent PNG and uploaded: see upload custom symbols.
Symbols keep their size on the plan as you zoom (since November 17, 2026), like walls and furniture: an outlet or switch is drawn at the size an installation plan at about 1:50 uses (a European socket's half-circle is about 8 in / 20 cm across), so zooming out no longer buries the walls under oversized marks. They stop shrinking at about a third of that size and stop growing at one and a half times it, so they stay readable at any zoom. Device names, circuit-line names and room name tags shrink with the plan when you zoom out, down to half size, and never grow past their normal size. Exports use the same plan size, so a printed sheet looks like the plan.
Symbols → US: outlet and switch tiles, Upload custom symbol and Circuit line. - 3
Put outlets and switches on walls
Outlets and switches are wall devices: tap the tile, tap +Add, and the banner asks you to tap a wall. Tap where the device goes and it sits flush on that wall at its standard height. Add as many as you need. Drag a device along its wall to move it, or onto another wall to move it there. Interior walls have two faces. A device lands on the face you tapped from, so tap from inside the room it serves. To move it to the other face later, use In / Out in its settings. In the example, the double outlet behind the TV sits on the living-room face of the bedroom wall: Out is picked because the tap came from the bedroom side. Devices can't go on a curved wall yet (Doors, windows and outlets can't go on a curved wall yet); put them on a straight wall.
An interior wall: In / Out picks which room the outlets face. - 4
Lights, detectors and other room symbols
Everything that isn't an outlet or switch drops into the room like furniture: tap the tile, tap +Add, and it lands in the middle of the room; drag it to where the fixture is. That covers ceiling, recessed, pendant and track lights, the ceiling fan, detectors, jacks, Wi-Fi, cameras, the electrical panel, junction box, valves, vents and the generic markers. Ceiling items are drawn over whatever is below them (a light over the island is not on the island). Three shared symbols hang on a wall instead: Wall Light, Under-Cabinet Light and Doorbell. Tap a wall to place them; they sit flush on its face and stay on the wall when you drag them. (Wall lights placed before this behaviour existed stay free.) Floor Outlet is a free symbol you can put anywhere, for example under a sofa that floats in the room. Select any room symbol to resize it, colour it, rotate it or rename it. A renamed symbol shows its name on the plan, like a device.
Room symbols drop at the centre and drag anywhere. - 5
A device's settings: kind, Mount height, distances, name
Select an outlet or switch (tap its symbol beside the wall) and its settings card opens: - Name (the first box) starts as Outlet or Switch. Type a breaker number or a description and press Enter. Only a name you typed shows on the plan. - Along wall with two arrow boxes (← → on a wall that runs across the screen, ↑ ↓ on one that runs up and down): the distance along the wall to the nearest wall or opening on each side. Type a number to move the device exactly. The padlock beside each box locks that distance (next section). - In / Out: which face of the wall it is on. - Kind: a drop-down of every outlet and switch kind in the same pack, so a placed Duplex can become a GFCI, or a switch can become a socket, without placing it again. - Mount: the height of the bottom of the plate above the floor, from 0 to 10 ft. - Add outlet / Add switch: turns the device into a combination (see Outlet and switch combinations below). - The red trash can deletes it (so does the round red button by the symbol, or the Delete key). Default Mount heights (bottom of plate): most US outlets 12 in; GFCI 42 in (over a counter); 240V and Weatherproof 18 in; Dryer 30 in; Range 4 in; US switches 46 in (about 48 in to the centre); European sockets 12 in (about 30 cm) and European switches 41 in (about 104 cm). Change any of them per device.
An outlet's card: name, Along wall with a padlock per side, In/Out, kind, Mount, Add outlet / Add switch. - 6
Lock an outlet's or switch's distance along the wall
Electricians set out boxes from a fixed point: "the switch 15 cm from the door frame", "the outlet 4 ft from the corner". Lock that distance and it stays true when the plan changes around it.
To lock: select the outlet or switch and tap the padlock next to the Along wall box you want to keep (the tooltip says Lock this distance). With a mouse there is a second way: hover over the distance number on the plan and click the padlock that appears beside it, as for wall lengths. A locked side shows a closed blue padlock in the card and a small padlock beside its number on the plan. Tap it again (Unlock this distance) to unlock. Each side locks on its own; outlets and switches only (not doors or windows).
What a lock does:
You change With the distance locked The wall gets longer or shorter, or the wall or opening it is measured from moves The device keeps the locked distance and slides with that face. (Unlocked, it keeps its place as a share of the wall, so the distance changes.) You drag the device, type one of its distances or move it to another wall Refused, with the message That would move an outlet or switch whose distance along the wall is locked. To move it, select it and tap the padlock next to its distance. Both sides are locked and the wall length changes, or the device would no longer fit Refused the same way While either side is locked, both distance boxes are read-only (no pencil) and the numbers on the plan can't be tapped to type. A copy made with Duplicate or paste is not locked.
Use it for the devices whose position matters to the installer: the switch by the door frame, the outlet centred behind a TV or a bed, counter outlets set out from a sink. Leave the rest unlocked so they move with the wall.
Locked: the padlock beside the right-hand distance turns blue, and the plan's number shows a padlock. - 7
Moving a locked device
Try to drag a locked outlet and nothing moves: an amber note explains why and how to unlock it. That protects a set-out you agreed with the electrician from an accidental drag while you arrange furniture. To move it on purpose, select it, tap the blue padlock to unlock, move it, then lock again if you want. Undo also takes a lock off if you locked the wrong side.
Dragging a locked outlet: refused, with how to unlock it. - 8
Outlet and switch combinations
Real installations group devices at one spot: a two- or three-gang frame of sockets, a light switch with a socket right below it, a row of switches by the door. In RoomSketch3D that is a combination: one spot on the wall holding up to 5 devices, each with its own kind, name and (when stacked) its own height. Two ways to make one: 1. Select a device and tap Add outlet or Add switch. The new device joins the same frame. It starts as a Duplex outlet or a Single switch (on a European device, an Earthed socket or a One-Way switch); change its kind in its row. 2. Drag one outlet or switch onto another. When it is right on top of the other symbol, a blue Drop to combine label appears; let go and they become one combination. A device placed with +Add right on top of an existing one joins it the same way. Both must be on the same face of the same wall, and the drop has to land within about an inch of the other symbol, so two outlets placed side by side stay two outlets. On the plan, side by side devices draw their own symbols inside a thin frame (the small 2, USB and IP44 marks sit inside the frame). Stacked devices draw as separate symbols without a frame, each with its height from the floor printed beside it (see Stacked devices: the height of each below). The combination moves, flips In / Out and deletes as one; circuit lines can end on any single device in it.
Drag an outlet onto a switch: Drop to combine. - 9
Combination settings: side by side or stacked, one row per device
Select a combination and its card lists every device on its own line: six-dot handle · number · kind · name · Mount (stacked only) · Separate · Remove. - Layout → Side by side: the devices sit next to each other in one frame at the same height; one Mount box sets the whole frame. - Layout → Stacked: one above the other, each with its own Mount. Because a floor plan can't show height, a stacked combination is drawn outward from the wall, the first device nearest the wall, and each device's height is printed beside it. A new device added to a stacked combination starts one plate (2.8 in, the 71 mm European frame pitch) below the lowest one, or above it when that would go below the floor. - Automatic layout when you drag: two devices at the same height join Side by side; at different heights (a switch dropped on an outlet) they join Stacked and keep both heights. - Name: the first device uses the card's main name box; every other device has its own Name box. The plan shows the names together, separated by a dot (for example Entry · Living lights). - Separate (the broken-link button) takes that device out and places it on its own, 6 in along the same wall. - Remove (its red trash can) deletes just that device. Removing the first one makes the next one the first, and lines on it stay connected. - The six-dot handle at the start of a row drags that device to another place in the list (see Reorder the devices in a group). - The trash can at the bottom of the card deletes the whole combination. The example's front-door switch is a side-by-side pair: Switch (Single) and Switch (Dimmer) named Living lights, Mount 3 ft 10 in. The kitchen wall has a stacked Switch (Single) at 3 ft 10 in over an Outlet (Duplex) at 1 ft.
Stacked: every device gets its own row and Mount, and the plan prints 46" and 12". - 10
Stacked devices: the height of each, printed on the plan
Since November 17, 2026 a Stacked combination reads like an electrician's installation plan: each device has its own symbol with no shared frame, and its height from the floor is printed beside it. A light switch at about 1 m with a socket at 30 cm under it shows both numbers at a glance, so nobody has to open the settings to find the heights. - The number is the same as the device's Mount: the height of the bottom of the plate. - On a metric plan it is in whole centimetres (105, 30); on an imperial plan in whole inches (46", 12"). A Mount of 3 ft 7.2 in prints as 43". - It sits to the right of the symbol on a wall that runs across the screen (below it on a wall that runs up and down), past the symbol's own tag (2, USB, IP44 …). - It prints on PNG, JPG and PDF exports too. The DXF (CAD) export draws the devices without the numbers (checked on a real DXF). - Side by side combinations keep their frame and show no heights: every device in them is at the same height, set by the one Mount box. Nothing about a saved plan changes: existing stacked combinations are only drawn this new way. To change a height, select the combination and edit that device's Mount.
Stacked devices, no frame, height beside each; side-by-side frames (middle) show none. - 11
Reorder the devices in a group
The order of the rows is the order on the wall: side by side, the first device is at one end of the frame; stacked, the first is nearest the wall on the plan. To change it, select the combination and drag a device by its handle (the six dots at the start of its row, tooltip Drag to reorder) up or down the list. The rows follow your finger or mouse while you drag, and the change is made once when you let go, so a single Undo puts it back. With a keyboard, focus a handle and press Arrow Up or Arrow Down to move that device one place. Circuit lines stay connected to the same devices: in the example, moving the dimmer named Living lights to the first place moves the Breaker 3 line's end with it. The device that ends up first becomes the group's main device, so its name moves into the card's main name box; side by side the frame keeps its height, stacked each device keeps its own Mount.
Drag by the six dots; the rows reorder as you drag, and the line stays on the dimmer. - 12
Side-by-side frames: double switches and multi-gang outlets
Side by side is the multi-gang box: two or three switches by a door, or a double or triple outlet over a desk or behind a TV. Change each row's kind to say exactly what is in the box (a single switch next to a dimmer, a duplex next to a USB outlet, three Schuko sockets with one USB socket). When should you use a combination rather than one symbol such as Outlet (Quad), Switch (Double) or Socket (Triple)? Use the single symbol when the device really is one part (a two-gang rocker switch, a quad receptacle) and you don't need to tell its halves apart. Use a combination when the parts are different kinds, carry different names or breakers, or connect to different circuit lines. Each device in a combination counts on its own in the legend and the circuit list.
Add switch made a two-gang frame; the second device is now a dimmer named Living lights. - 13
Names, breaker numbers and the layer that shows them
Give each device, room symbol and circuit line a name that a person at the panel can match: Breaker 12, B12 – Kitchen counter, Living lights. Use the same wording everywhere. Two devices on one breaker can share a name. Names, devices, room symbols and circuit lines all show on the plan while View & Layers → Show outlets, switches & symbols is ticked (View & Layers is the stacked-sheets button, first in the toolbar above the plan; the row is under Furniture & electrical). Untick it while you arrange furniture: everything electrical hides and can't be tapped, but nothing is deleted. The row switches itself on when you place a device or open a plan that has them, unless you turned it off yourself. The indented Circuit lines row under it hides just the lines, and Show furniture hides the furniture instead. Your layer choices are saved with the design, so it opens the same way on any device. The Electrical plan view at the top of the menu turns the electrical rows on in one tick (see The Electrical plan view below). The export dialog's Electrical symbols and Circuit lines boxes start the way these rows are set. On exports, the Labels option prints the names. See electrical plan outlets switches symbols for a breaker-map walkthrough.
View & Layers → Furniture & electrical: Show outlets, switches & symbols and its Circuit lines row. - 14
Draw circuit lines
A circuit line shows which devices share a feed: a switch and the lights it runs, or the outlets on one breaker. In the Symbols panel tap Circuit line (it changes to Exit circuit line). The hint across the plan reads: Click each symbol to connect them. Click empty space to add a bend; drag a bend to move it. Double-click, or click the last symbol again, to finish · Enter to finish · Esc to cancel (on touch: Tap … Tap the last symbol again to finish · Done to finish · ✕ to cancel). 1. Tap the first device. The first tap has to be a symbol; a tap on empty floor shows Tap a symbol to connect it. 2. Tap the next devices in wiring order. Any symbol works: outlets, switches, one device of a combination, lights, jacks, your own uploads. 3. Finish the line: press Enter, tap Done, double-click, or tap the last symbol again. The line gets a name (Circuit 1, Circuit 2 …) and the tool stays on for the next one. One switch to two lights (a double switch, a switch feeding a light and a fan): draw switch → first light and finish. Then tap the switch again to start the second line from it, tap the second light, and finish. (Until November 17, 2026 tapping the first device again started a branch automatically; now it saves the line and stops, see Finish, loop, or keep an unfinished line.) A line attaches to its symbols: move a device and the line follows; delete a device and it comes off its lines (an end takes its piece with it, a middle device's neighbours join up). Lines draw on every export.
The armed tool and its hint, with Done and ✕. - 15
Route a line along the walls with bends
Straight device-to-device lines cut across the room. Real wiring runs along walls and through ceilings, and an installation plan draws it that way. While drawing, tap an empty spot to add a bend: the line goes from the last device to that point, then on to the next thing you tap. A bend that is close to straight across or straight up and down on your screen (within about 12 degrees) is squared up for you, so right-angle runs come out clean, even on a rotated plan. The dashed preview follows your pointer to the next spot, and stops following it when the pointer leaves the plan, so it no longer trails you to the Done button. In the example, Breaker 7 starts at the outlet on the right wall, bends at the corner, and runs along the bottom wall to the outlets at both ends of the sofa. Breaker 3 leaves the dimmer, goes straight up the room, bends, and runs across to the ceiling light. A line always runs from symbol to symbol: you can't end it on a bend. Backspace (or Undo) removes the last point you placed, device or bend.
Outlet → bend → next symbol: each tap on empty space is a bend. - 16
Move a bend while you are still drawing
Placed a bend in the wrong spot? You no longer have to finish the line first. While drawing, press on the bend's small square and drag it to where it belongs; it doesn't add a new point. Then carry on tapping symbols and bends. On a finished line you can still drag bends too (see Edit a finished line).
Drag a bend's square while drawing; the line follows. - 17
Finish, loop, or keep an unfinished line
Four ways to finish, all doing the same thing: Enter, Done in the hint bar, a double-click, or a tap on the last symbol again. With a mouse, a double-click or a second click on the last outlet means you never have to drag the dashed preview to the Done button. - Tap the first symbol again to save the line and stop. If the line already reached another device, it is saved as drawn. If it is one device plus bends, it runs back to that device: a loop (a ring of outlets, or a run that leaves a junction box and comes back). A blue note confirms it: Line saved. Tap a symbol to start the next line. It doesn't start a new line by itself any more; tap a symbol (the same switch, for a second light) to start the next one. - Finish before the line reaches a second symbol and the bends you drew are kept, with an amber note: A line has to end on a symbol. Tap a symbol to finish it, or ✕ to cancel. An accidental double-click no longer throws a half-drawn run away. A single device with no bends is still dropped. - Esc (or ✕) cancels the draft; a second Esc leaves the tool.
Finished too early: the bends are kept and the note says what's missing. - 18
A loop back to the first symbol
Here the line leaves the outlet by the sofa, takes two bends and comes back to the same outlet: tapping that outlet again saved it as Circuit 5, and the note says Line saved. Tap a symbol to start the next line. Name it like any other circuit.
Tap the first symbol again: the loop is saved and drawing stops. - 19
Edit a finished line: extend, bend, remove
Tap a line (or its name) to select it. On the plan: - A blue + past each end (Add to this line): tap it, then tap more symbols (or empty space for bends) and Done. They join the same circuit, name and colour. - A small + in the middle of each stretch that is long enough: drag it to add a bend there. It slides aside so it never hides under a name plate. - Drag a bend to move it; it lines up with the points on either side when it comes close. - Tap a dot or a bend, then the red − (Remove from this line). A bend just goes; a device's dot leaves the device on the plan and takes it off the line. If one device would be left, the line is deleted. - Drag an end dot onto another symbol to re-point that end. - The round red trash button on the line deletes the whole line (the devices stay). The card repeats this: Drag a + in the middle of the line to add a bend, and drag a bend to move it. Tap + at an end to add symbols. Tap a dot or bend to remove it, or drag a dot onto another symbol. Selected handles keep their full size at any zoom so they stay easy to grab, while an unselected line's end dots and name shrink when you zoom out.
Selected: + at the ends, dots and bends on the line, and the line's card. - 20
Name, colour and line style of a circuit
The selected line's card has its name (type Breaker 3 and press Enter; clearing it puts back Circuit N), Color and Line: Solid or Dashed (dashed is the default and how every line drawn before November 2026 looks). Delete removes the line, not the devices. A common convention: dashed for switch legs and outlet circuits, solid for a home run to the panel, or one colour per breaker. RoomSketch3D doesn't enforce a meaning; the Circuits table on the export shows each line with its own colour and style next to its name, so the sheet explains itself.
Breaker 3 set to Solid; Breaker 5 and Breaker 7 stay dashed. - 21
Any colour for a circuit line
Six preset colours (blue, red, green, orange, purple, black) cover most plans, but a panel with twenty breakers needs more. Since November 17, 2026, the rainbow circle after the presets (tooltip Custom color) opens your device's colour picker: pick any colour and the line changes on the plan while you pick; closing the picker saves it as one step, so one Undo reverts it. The rainbow circle gets a blue ring while the line has a custom colour. The export's Circuits table shows the same colour next to the line's name. The same rainbow circle is now the "any colour" button everywhere in the app: furniture, doors, awnings and rooms use it too. Pickers look different on iPhone, Android and computers; on a phone, tap outside the picker to close it.
The rainbow circle: any colour, here teal for Breaker 7. - 22
The settings card: move it, reset it; phones
On a tablet or computer, the settings of a selected outlet, switch, door, window or circuit line open in the same floating card as furniture settings. It steps aside so it doesn't cover what you selected. Drag it by its top row (the dotted grip) to put it anywhere; Reset then appears and puts it back at the bottom of the plan. It opens where you last left it, for furniture too. On a phone the same settings are a panel along the bottom of the screen; in a combination the kind list there is narrower, so the kind name may be cut short (tap it to see the full list).
Dragged out of the way: Reset puts it back. - 23
Right-click shortcuts (mouse)
With a mouse or trackpad, a right-click on the plan acts on what's under the pointer:
Right-click on What happens A room symbol (light, fan, detector, jack, Floor Outlet, your uploads) A menu titled with its name: Edit, Duplicate, Rotate 90°, Lock in place / Unlock, Delete An outlet or switch on a wall It's selected and its settings card opens (no menu); the card has the kind, Mount, Add outlet / Add switch and the trash can A circuit line No menu of its own: the right-click goes to whatever is under the line (the room menu, or a piece of furniture the line crosses). Tap or click the line to select it and use its card Empty floor The room menu, with Rename room On a touch screen a long-press keeps opening the room menu, as before. Lock in place on a light or detector stops it being dragged by accident while you draw circuits around it.
Right-click a light: its own menu, titled Ceiling Light. - 24
On a phone
Everything above works on a phone: the Symbols pill opens the panel, a tap places or selects, dragging a selected device moves it, and Done / ✕ in the circuit hint replace Enter and Esc. A selected device's settings fill the bottom of the screen with the same rows: Along wall with its two padlocks, In / Out, Layout, one row per device with its six-dot handle, Mount, Separate and Remove, and Add outlet / Add switch. The hover padlock on the plan's numbers is mouse-only; on a phone use the padlocks in the panel. Zoom in before dragging one device onto another: the drop has to land right on the other symbol. To finish a circuit line, tap Done or tap the last symbol again.
Phone: the same settings in a bottom panel; the kind names are cut short. - 25
The Electrical plan view: everything electrical, no furniture
Since November 17, 2026 the View & Layers menu (the stacked-sheets button, first in the toolbar) starts with three views: Floor plan, Interior design and Electrical plan. A view is a shortcut for a set of layers, and views are checkboxes, not modes:
- Tick a view to turn all of its layers on. - Untick it to turn them off again, except layers another ticked view also uses. - Turning a single layer on or off never changes which views are ticked.
View Layers it turns on Floor plan Exterior and interior dimensions, room labels, furniture Interior design Room labels, furniture, furniture labels, flooring, tile layouts, people for scale Electrical plan Exterior dimensions, room labels, outlets, switches & symbols, circuit lines For the electrician's view on screen: tick Electrical plan, then untick Floor plan. Furniture and interior dimensions disappear, and outlets, switches, lights, circuit lines, room names and the outer measurements stay, so a tap can't grab a sofa while you draw lines. Tick Floor plan again to get the furniture back.
Careful: unticking Electrical plan also hides the outlets, switches and circuit lines (unless another ticked view uses them); they are hidden, not deleted. Tick the view again, or tick Show outlets, switches & symbols and Circuit lines in the list.
+ Save current as view… at the top keeps your own mix under a name (for example Electrician – no dims). Views and layer choices are saved with the design, so it opens the way you left it, on any device.
Electrical plan ticked, Floor plan unticked: furniture off, electrics on. - 26
The plan in the Electrical plan view
The example with only Electrical plan ticked: walls, doors, windows, room names, the outer dimensions, every outlet and switch with its tag, the stacked heights, lights, the smoke detector and the three coloured circuits. Room colours stay on screen. This is also a good way to check the plan before exporting, because the export dialog starts with the same views ticked.
The Electrical plan view on screen: furniture hidden, electrics and outer dimensions kept. - 27
The symbol legend and the circuit table
Export with Symbol legend & circuit table ticked (the export's Electrical plan view ticks it for you; it works on any export) and two tables print under the drawing: - Symbol legend: one row per kind of outlet, switch and room symbol on the plan, with its mark and a count. Every device of a combination counts on its own (the example's legend lists Outlet (Duplex) ×5, Switch (Single) ×2, Switch (Dimmer) ×1, Outlet (USB) ×1). - Circuits: one row per circuit line, with a sample of its colour and style (solid or dashed), its name, and the devices on it in run order. A device's own name is used when it has one (Breaker 3 — Living lights, Ceiling Light); devices of the same kind are merged with a count (Breaker 7 — Outlet (Duplex) ×3). Bends aren't devices, so they don't appear. When Circuit lines is unticked, the Circuits table is left out and the legend stays. The footer gives the plan's name, overall size, gross and usable area and the date. That is what an electrician needs to price the job: how many of each device and what is on each breaker.
From a real PNG export: the symbol legend and the circuit table. - 28
Export, print and CAD: what each one contains
Open Export / Print / Share → PNG/JPG/PDF or Print. Choose Export (or Print), a Format (PNG, JPG, PDF) and a paper size. Below them:
Views (since November 17, 2026): the same Floor plan, Interior design and Electrical plan checkboxes as on screen, ticked the way the plan shows them, plus any views you saved. Ticking or unticking one flips its options below with the same rule as on screen. In the dialog, the Electrical plan view also ticks Symbol legend & circuit table, and the Floor plan and Interior design views also tick Room tints.
Options (one set for every export):
- Symbol legend & circuit table: the legend and circuit table under the plan. This replaced the old Electrical plan checkbox, and you can add it to any export, furnished or not. - Electrical symbols and Circuit lines: whether the devices and the lines go in the file. They start the way the plan shows them. Unticking Electrical symbols takes the lines with it. - Furniture: every piece except the electrical symbols and lights. - Labels: prints device and circuit names (and room names). On a phone it starts unticked. - Room tints: the room colour fills. Untick it (or tick Black & white) for a plain line drawing. - Exterior / Interior dimensions, Grid, Elevation views and the rest work as on any export.
The electrician's sheet in one go: under Views, untick Floor plan and tick Electrical plan. Furniture, room tints and interior dimensions go off; symbols, circuit lines, labels, outer dimensions and the legend & circuit table come on. Check Room tints before you export: it is only switched off when you untick Floor plan in the dialog. If the plan was already in the Electrical plan view when you opened the dialog, or your last export had it off, the box keeps that state, so tick or untick it yourself.
Output What you get PNG / JPG One image of the plan with the legend and circuit table when ticked (checked on a PNG export) PDF The same sheet as one page, for printing or email (checked) Print tab The same sheet sent to your printer (not separately tested) DXF (Export / Print / Share → DXF → Export DXF) CAD drawing in inches with an ELECTRICAL layer: each outlet and switch (every device of a combination, side by side) as a circle mark with its tag (GFCI, R, D, USB …), device names, and each circuit as a polyline with its name. Room symbols such as lights export as labelled footprints. No legend table, and no height numbers for stacked devices. The DXF always carries everything (no Views or layer boxes); switch CAD layers off instead. (Checked on a real DXF.) See print your floor plan and export autocad dxf for paper sizes and CAD details.
Views: Electrical plan on, Floor plan off. The legend & circuit table comes with it. - 29
The exported electrical plan
This is the living room and kitchen from the real PNG export of the example, made with the Electrical plan view as above. Furniture and room colours are gone; the walls, the door swings, the room name, the outer dimensions, every outlet and switch with its tag, the side-by-side frame by the door, the stacked kitchen pair with 46" and 12", the lights and detector, the three coloured circuits with their bends, and the device names Living lights and Breaker 14 remain. Hand it to an electrician, attach it to a permit application as a sketch, or tape it inside the panel door.
The exported sheet: devices, frames, heights, names and routed circuits; no furniture. - 30
Plans per trade: electrician, symbols only, furniture
One design can give each trade its own sheet. Nothing is copied or duplicated: you export the same plan several times with different views and boxes ticked. Open Export / Print / Share → PNG/JPG/PDF or Print once per sheet; each time it opens with the views the plan shows.
Sheet Who it's for In the export dialog Electrician's plan The electrician pricing and wiring the job Views: untick Floor plan, tick Electrical plan. Check Room tints is off Symbols-only plan Device placement, a client sign-off, a permit sketch, a plan before circuits are decided As the electrician's plan, then untick Circuit lines Furniture plan The client, the furniture installer, the flooring or painting crew Keep Floor plan ticked (and Interior design if you like), untick Electrical symbols, tick Room tints if you want colour Furnished plan with the electrics over it A walkthrough of outlet positions around the furniture Keep Floor plan, keep Electrical symbols and Circuit lines, tick Symbol legend & circuit table if you want the tables What each one contains, checked on real PNG exports of the example plan (November 17, 2026):
- Electrician's plan: walls, doors, windows, room names, outer dimensions, every outlet, switch, combination and light, the stacked heights, the routed circuit lines with their names, the Symbol legend with counts and the Circuits table. No furniture, no colour fills, no interior dimensions. - Symbols-only plan: the same without the lines and without the Circuits table (the legend stays). Named devices keep their names. - Furniture plan: the furnished plan with room colours, interior dimensions and no outlets, switches, lights or circuit lines.
To set up the same thing on screen first, use the views in View & Layers (see The Electrical plan view): the export starts from them. Export each sheet as PNG or PDF; repeat for each floor. To keep a sheet's mix for next time, save it as your own view with + Save current as view…; it then appears as a checkbox in the export dialog too.
The Views and Options for each sheet: electrician, symbols only, furniture plan. - 31
The three plans side by side
The kitchen and living room of the example from the three real exports. Top: the electrician's plan, with Breaker 5 (green, dashed) routed from the kitchen switch around the recessed lights to the pendants, Breaker 3 (red, solid) from the dimmer to the ceiling light, and Breaker 7 (blue, dashed) along the outlets. Middle: symbols only: the same devices, names and heights, no lines. Bottom: the furniture plan, with the island, kitchen run, sofa, rug and armchair and no electrical marks. Send the electrician the top sheet (plus the cable list below), the client or an inspector the middle one when only positions matter, and everyone else the bottom one. If a sheet should show the furniture under the electrics, keep Floor plan ticked with Electrical symbols and Circuit lines: symbols and lines print over the furnished plan, and you can add the legend & circuit table to it.
Top to bottom: electrician, symbols only, furniture plan, all from one design. - 32
The cable list: length of every run, in Excel
On a computer, Export / Print / Share → Schedules (Excel) → Cable runs turns your circuit lines into a cable pull list. Each line is split at every device it connects, and each stretch is one row: Circuit (its name, such as Breaker 5), Run (1, 2, 3 … in drawing order), From and From room, To and To room, and Length along the line with every bend included, in inches or centimetres. Download CSV saves that table; Download all (Excel) saves one .xlsx with the Rooms, Items by room and Cable runs sheets. In the example, Breaker 5 gives four runs: 72.1 in (switch to the first recessed light, around the corner), 65 in, 71 in and 24 in, 232.1 in or about 19 ft 4 in in all. Total any circuit in Excel with =SUMIF(A:A,"Breaker 5",G:G) or a PivotTable. Route the lines the way the cable goes, because the length is the drawn path. The length is measured on the plan, so it doesn't include the drops from the ceiling or floor to each box (work them out from each device's Mount and your ceiling height), the run to the panel unless you drew one to an Electrical Panel symbol, or slack. The Items by room sheet counts every outlet, switch and light per room. Phones and the apps don't have Schedules yet; there, the export's circuit table (tick Symbol legend & circuit table) names the devices on each circuit, without lengths. Full details: schedules room list and cable list.
Schedules → Cable runs: one row per stretch between two devices, length along the line. - 33
Outlets and switches in 3D
In the 3D view, outlets and switches appear on their walls at their Mount heights, drawn at real plate size (slightly enlarged so you can find them): US receptacles and toggles, Decora-style GFCI and AFCI, European 80 mm frames with Schuko sockets and rockers. A combination shows as one multi-gang plate or frame with each device in its own slot: side by side in a row, or one above the other at each device's height. Floor Outlet also shows in 3D. Other plan symbols (lights, detectors, jacks, vents, uploads) are 2D only; for lights you can see in 3D, add fixtures from the Indoor catalog (for example the flush ceiling or pendant lights). Tick Dollhouse (top left) and, in the View options menu (bottom right), High quality to look at one wall closely. The same View options menu has Outlets & switches to hide them in 3D, and Furniture, which also hides the people placed for scale; 3D opens showing what the plan shows. Known issue (US stacked plates, checked November 17, 2026): when you add an outlet to a US switch with Add outlet and Stacked, the outlet gets a Mount 2.8 in (one 71 mm European frame) below the switch. A US wall plate is about 4.5 in tall, so in 3D the two plates overlap; the plan and exports are fine. Until that is fixed, type the real heights in each Mount box (for example 46 in for the switch and 12 in for the outlet, or 42 in over a counter), which also prints the right numbers on the plan. European stacked frames are not affected.
In 3D, left to right: US duplex + USB, US three-gang switch (single, dimmer, 3-way), European switch over socket, European triple socket with USB. - 34
Drawing a German or European plan
Pick Europe in the Symbols panel for IEC-style marks: a half-circle socket on a short stem, earthed sockets with the extra bar, 2 / 3 for multiple sockets, IP44 outdoors, 400V for three-phase, and switches as a small circle with one or two strokes. The kind list of a European device offers European kinds only, so a German plan stays consistent. German plans usually show Kombinationen: a switch with a socket under it beside the door, and two- or three-gang socket frames over desks and worktops. Make them as combinations (drag one onto the other, or Add outlet / Add switch). A switch dragged onto a socket keeps both heights and stacks; Add outlet on a stacked switch puts the socket one 71 mm frame below it. On a metric plan each stacked device's height prints beside it in centimetres, as on a German Installationsplan. Heights in Germany: DIN 18015-3 recommends 105 cm above the finished floor for switches and sockets in the middle zone and 30 cm in the lower zone, and keeps cable runs in installation zones (horizontal bands 15–45 cm below the ceiling, 100–130 cm and 15–45 cm above the floor; vertical bands 10–30 cm beside doors, windows and corners) so nobody drills into a hidden cable. RoomSketch3D's Mount is the bottom of the plate: for a box centred at 105 cm, type about 101 cm (half an 80 mm frame lower); for 30 cm, about 26 cm. Check the heights your electrician uses; the standard gives preferred heights, and kitchen worktop sockets are set by the worktop.
One wall, both packs: stacked pairs show heights, side-by-side groups keep a frame. - 35
European combinations, row by row
A German entry combination: Switch (One-Way) at Mount 3 ft 5 in (about 104 cm) with Socket (Earthed) below it at 3 ft 2.2 in, Stacked; the plan prints 41" and 38" beside them (on a metric plan, 104 and 97). A worktop frame: Socket (Earthed), Socket (Earthed) and Socket (USB) side by side, one Mount for the frame. Units follow your settings, so in metres the boxes read in centimetres.
Schalter-Steckdosen-Kombination: one-way switch over an earthed socket, heights on the plan. - 36
US placement rules to check your plan against
RoomSketch3D draws what you place; it doesn't check code. These are the rules most US electrical plans are checked against (2021 International Residential Code, Chapter 39, which follows the National Electrical Code, NEC 210.52 for receptacle spacing). Local amendments vary, and the inspector and your electrician have the final word.
Where Rule Section Any wall in a living area No point along the floor line more than 6 ft from an outlet (the "12-ft rule": outlets at most 12 ft apart). Walls 2 ft or wider count IRC E3901.2.1, E3901.2.2 Kitchen counter Every counter space 12 in or wider; no point along the wall line more than 24 in from an outlet (about every 4 ft) E3901.4.1 Island / peninsula One outlet for the first 9 sq ft of counter, plus one per extra 18 sq ft; a peninsula needs one within 2 ft of its end E3901.4.2 Counter outlet height On the counter or up to 20 in above it E3901.4.3 Bathroom One within 36 in of each basin's outside edge E3901.6 Outdoors One at the front and back, no higher than 6 ft 6 in above grade E3901.7 Foyer over 60 sq ft An outlet in each wall space 3 ft or wider E3901.11 GFCI Bathrooms, garages, outdoors, crawl spaces, basements, kitchen counters, within 6 ft of a sink or tub, laundry areas and more E3902 AFCI Circuits in kitchens, living and family rooms, dining rooms, bedrooms, closets, hallways, laundry areas and similar rooms E3902.20 Tamper-resistant 15 A and 20 A, 125 V and 250 V receptacles in a home E4002.14 Switched light A wall-switch-controlled light in every habitable room, kitchen and bathroom; stairs with 6 or more risers get a switch at each level E3903.2, E3903.3.1 Switch height limit Handle no higher than 6 ft 7 in E4001.6 Outlets more than 5.5 ft above the floor don't count toward the spacing rule (E3901.1).
Heights are mostly custom, not code. The code sets no height for an ordinary outlet. Common practice is 12–18 in to the bottom or centre of an outlet, about 42–44 in for counter outlets (above a 36 in counter and backsplash), and 44–48 in to the centre of a switch. For accessible design, the 2010 ADA Standards put operable parts between 15 in and 48 in above the floor (308.2.1, 308.3.1).
In RoomSketch3D: use the tags (GFCI, AFCI, TR, WP) to show protection, the Along wall boxes to check the 12-ft and 24-in spacing, and Mount for heights.
Along wall shows the gap to the next wall or opening on each side: useful for the 6-ft rule. - 37
Keyboard shortcuts and undo
Key While drawing a circuit Otherwise Enter Finish the line Confirms a typed name or number Esc Cancel the draft (press again to leave the tool) Deselect Backspace Remove the last point (device or bend) Delete the selected item Delete — Delete the selected item Ctrl/Cmd + Z, Shift + Ctrl/Cmd + Z Step the draft back / forward Undo / redo any change, including combining, separating and line edits On touch, use Done and ✕ in the hint bar and the Undo / Redo arrows in the toolbar. See keyboard shortcuts and undo redo.
- 38
What it can't do yet, and the workaround
You want Today Workaround A code check (spacing, GFCI, loads) Not available; nothing is validated Check against the rules above with the Along wall boxes and tags; your electrician sizes circuits and wire A panel schedule with breaker sizes and wire gauges The Circuits list names lines and devices; Schedules gives run lengths Put the size in the name: Breaker 12 – 20A kitchen Cable lengths with the drops to each box Schedules → Cable runs measures along the plan only Add each drop from the device's Mount and the ceiling height, plus the run to the panel and slack A cable list on a phone Schedules is on a computer only Open the design on a computer; on the phone, the Electrical plan export's Circuits list names the devices per circuit Several trade sheets in one export One sheet per export Export once per trade with different views ticked (see Plans per trade); save each mix as a view Heights of stacked devices in the DXF Printed on the plan, PNG, JPG and PDF only Put the height in the device's name, or note it in CAD Heights on side-by-side groups Only stacked devices print a height The frame's single Mount is in the card; add it to the name if the sheet needs it A US switch and outlet stacked with Add outlet, in 3D The plates overlap (they are 2.8 in apart) Type the real heights in each Mount (e.g. 46 in and 12 in) Locking a door's or window's distance Locks are for outlets and switches Lock the wall length instead, or note the distance Trade layers in the DXF The DXF always carries everything Turn CAD layers off; electrics are on the ELECTRICAL layer A right-click menu on a circuit line Not yet; the right-click goes to what's under it Click the line to select it and use its card (or its red delete button) Curved switch legs Lines are straight segments Add bends to route the line; dashed reads as a switch leg Lights, fans, jacks in 3D Only outlets, switches and the Floor Outlet show in 3D Add catalog light fixtures from Indoor for the 3D view A combination of lights, data jacks or room symbols Combinations are for outlets and switches Place the symbols next to each other and give them the same name More than 5 devices at one spot Up to 5 Two combinations side by side US and European kinds in one combination The kind list keeps one pack Pick one pack for the whole plan (mixing confuses installers anyway) An outlet on a curved wall Not yet Straighten that stretch or use the nearest straight wall A symbol that isn't in the library Not built in Draw it as a transparent PNG: upload custom symbols
Tips
Place furniture first, then devices
Outlets follow the furniture: one each side of a bed, behind the TV, at the desk, where the sofa won't block it. Switches follow the doors: inside the room on the latch side.
One name per breaker
Name the circuit line and every device on it the same way (Breaker 7). The export's circuit list then reads exactly like the labels in your panel.
Route lines, don't cross rooms
Tap the corners while you draw. Runs along walls are easier to read and closer to how cable really goes; a near-straight bend squares itself.
Hide the electrics while you furnish
Untick View & Layers → Show outlets, switches & symbols to move furniture without grabbing a device; tick it again for the electrical pass.
Wire in the Electrical plan view
In View & Layers tick Electrical plan and untick Floor plan: outlets, lights and circuits stay, and a tap can't grab a sofa or a rug by mistake while you draw lines.
Set the views before you export
The export dialog starts with the views and layers the plan shows, so what you see is what you get. Glance at Room tints and Labels anyway.
Lock the set-out points
Lock the distance of the devices the electrician measures from (switch by the door frame, outlet behind the TV). They then follow wall changes and can't be dragged by accident.
Type real heights for stacked devices
The plan prints each stacked device's Mount. Typing the heights your electrician uses (46 in switch, 12 in outlet; 105/30 cm centres in Germany minus half a plate) makes the sheet self-explanatory.
One colour per breaker
With the rainbow circle, every breaker can have its own colour; the export's circuit table repeats it next to the name.
Use the tags as notes
A GFCI, AFCI, TR or WP tag tells the installer the protection you expect at that spot, without a separate note.
Zoom in to combine
The drop has to land on the other symbol (within about an inch on the wall). Zooming in makes it easy on a phone and prevents accidental combining.
Common confusions
Reading Mount as the centre height
Mount is the height of the bottom of the plate. A switch "at 48 in" to its centre has a Mount of about 46 in; a German socket at 105 cm centre is about 101 cm.
Tapping empty floor first
A circuit line has to start on a symbol. Tap a device first; after that, empty space adds bends.
Expecting the first device to start a branch
Tapping the first device again now saves the line and stops (or closes a loop). To run a second line from the same switch, tap the switch once more and continue.
Trying to drag a locked outlet
A locked distance refuses the move with an amber message. Unlock with the padlock beside the distance, move it, then lock again.
Unticking the Electrical plan view to hide only the lines
Unticking the view hides the outlets, switches and circuit lines together. To hide only the lines, untick the Circuit lines row instead.
Dropping a device near another and expecting it to combine
Combining needs the drop right on the other symbol, on the same face of the same wall. A device on the other face (In / Out) never combines; flip one first.
Deleting a device to take it off a line
Select the line, tap the device's dot and use the red − instead. Deleting removes the device from the plan.
Exporting with furniture and no legend
With only the Floor plan view ticked, the furniture covers the symbols and there is no legend. Untick Floor plan and tick Electrical plan, or tick Symbol legend & circuit table.
A layer hidden on screen goes missing from the file
The export boxes start from the plan's layers. If you hid outlets or circuit lines while furnishing, the dialog opens with Electrical symbols or Circuit lines unticked; tick them for the electrician's sheet.
Colour fills on the electrician's sheet
Room tints only turns off when you untick Floor plan inside the export dialog, and it keeps its last state between exports. Check the box before exporting.
Ordering cable from the plan lengths alone
Schedules measures along the plan. Add the vertical drops, the run to the panel and slack before you order.
Frequently asked questions
Can RoomSketch3D draw an electrical circuit diagram on a floor plan?
Yes. Place outlets, switches and lights with the Symbols panel, then use Circuit line to connect them in wiring order, with bends to route along the walls. Each line can be named after its breaker, given any colour and set solid or dashed, and the export's circuit table lists every circuit with its devices. It is a layout diagram on the floor plan, not a single-line schematic or a load calculation.
How do I put two outlets or an outlet and a switch in one box?
Select one device and tap Add outlet or Add switch, or drag one device onto the other until Drop to combine appears. Choose Side by side for a multi-gang frame or Stacked for one above the other. See outlet and switch combinations.
How do I make a circuit line follow the walls?
While drawing, tap empty spots where the line should turn. Each tap adds a bend, squared up when it is close to horizontal or vertical. On a finished line, drag the small + in the middle of a stretch to add a bend, or drag an existing bend.
Can I make circuit lines solid instead of dashed?
Yes. Select the line and pick Line → Solid in its card. Dashed is the default.
Can a circuit line be any colour?
Yes. Select the line and tap the rainbow circle after the six preset colours in its card; your device's colour picker opens and the line changes as you pick. One Undo reverts it. The export's circuit table shows the same colour.
How do I finish a circuit line?
Press Enter, tap Done, double-click, or click (tap) the last symbol again. Tapping the first symbol again also saves the line (closing a loop if the line only has bends after it) and stops. If you finish before reaching a second symbol, the bends are kept with a note that a line has to end on a symbol.
How do I run two lines from the same switch?
Draw the first line and finish it, then tap the switch again to start the second line from it. Tapping the first symbol no longer starts a new line by itself.
Can I lock an outlet's position on the wall?
Yes. Select it and tap the padlock next to its distance under Along wall (with a mouse you can also hover the distance on the plan and click the padlock). The outlet then keeps that distance when the wall or the opening it is measured from changes, and can't be dragged or typed until you unlock it.
Can the plan show the height of each outlet and switch?
For stacked devices, yes: each one prints its height from the floor beside its symbol, in whole centimetres on a metric plan or inches on an imperial one, on the plan and on PNG, JPG and PDF exports (not in the DXF). It is the device's Mount value, the bottom of the plate. Side-by-side groups and single devices show their height in the settings card.
Can I change the order of the switches in a group?
Yes. Select the group and drag a device by the six dots at the start of its row; Arrow Up / Arrow Down on a focused handle also moves it. Circuit lines stay connected to the same devices.
Why do the outlet symbols change size when I zoom?
Since November 17, 2026 outlet and switch symbols keep one size on the plan, like walls and furniture, so they shrink when you zoom out instead of covering the walls. They stop shrinking at about a third of their size, and circuit names and room tags stop at half size, so everything stays readable.
What height do outlets and switches get?
Mount (the bottom of the plate) defaults to 12 in for most US outlets, 42 in for GFCI, 18 in for 240V and weatherproof, 30 in for a dryer outlet, 4 in for a range outlet and 46 in for US switches; European sockets 12 in (about 30 cm) and switches 41 in (about 104 cm). Change it per device in the Mount box.
Do outlet and switch combinations print and export?
Yes. PNG, JPG and PDF draw side-by-side groups in a thin frame and stacked devices separately with their heights; the legend and circuit table count every device, the 3D view shows a plate or frame with a slot per device, and the DXF draws each device side by side on the ELECTRICAL layer, without heights. (PNG, PDF and DXF were checked on real exports.)
Does the DXF export include outlets, switches and circuits?
Yes, on a layer called ELECTRICAL: each outlet and switch as a circle mark with its tag, device names, and each circuit line as a polyline with its name. Lights and other room symbols export as labelled footprints. There is no legend table in the DXF.
Can I draw a German electrical plan (Elektroplan)?
Yes. Choose the Europe pack for IEC-style sockets and switches, build Schalter-Steckdosen combinations with Add outlet / Add switch, set Mount heights in centimetres if you work in metric, and route lines along the walls. DIN 18015-3 recommends 105 cm and 30 cm above the finished floor; type about 101 cm and 26 cm in Mount, since Mount is the bottom of the plate.
Why don't my lights show in 3D?
Plan symbols other than outlets, switches and the Floor Outlet are 2D marks. Add light fixtures from the Indoor catalog if you want to see them in 3D.
My outlets and lines disappeared. Are they deleted?
No. Open View & Layers and tick Show outlets, switches & symbols (and its Circuit lines row for the lines), or tick the Electrical plan view. Unticking the Electrical plan view hides them too. While they are off, the export dialog opens with Electrical symbols or Circuit lines unticked. In 3D, check View options → Outlets & switches.
How do I give the electrician a plan without furniture?
Export / Print / Share → PNG/JPG/PDF or Print; under Views untick Floor plan and tick Electrical plan. Furniture, room tints and interior dimensions go off, and symbols, circuit lines, labels and the Symbol legend & circuit table come on. Check Room tints is unticked before exporting. For the furniture-only plan, keep Floor plan and untick Electrical symbols.
Where did the Electrical plan checkbox in the export go?
Since November 17, 2026 Electrical plan is a view at the top of the export dialog (and of View & Layers). Its old job of adding the legend is the Symbol legend & circuit table option, which you can now add to any export.
Can I export the outlets and switches without the circuit lines?
Yes. Untick Circuit lines in the export Options (or untick View & Layers → Circuit lines first). With the Electrical plan view ticked you get a symbols-only sheet with the legend.
How much cable does each circuit need?
On a computer, Export / Print / Share → Schedules (Excel) → Cable runs lists every run between two devices with its length along the line, bends included. Total a circuit in Excel, then add the drops to each box, the run to the panel and slack. See schedules room list and cable list.
Is there a right-click menu for outlets and circuit lines?
With a mouse, right-clicking a light or other room symbol opens its menu (Edit, Duplicate, Rotate 90°, Lock in place, Delete). Right-clicking an outlet or switch selects it and opens its card. Circuit lines have no right-click menu yet: click the line to select it.
Does RoomSketch3D check my plan against the electrical code?
No. It draws what you place. Use the rules on this page to check spacing and protection, and have a licensed electrician and your local building department confirm it.
Sources
- 2021 International Residential Code, Chapter 39 — E3901.1, E3901.2.1, E3901.2.2, E3901.4.1–E3901.4.3, E3901.6, E3901.7, E3901.11 receptacle outlets; E3902 GFCI and AFCI; E3903.2, E3903.3.1 lighting outlets — Unamended 2021 IRC as adopted by Colorado, read on UpCodes. The IRC electrical chapters follow NFPA 70 (NEC), where the spacing rules are 210.52. Local codes vary.
- 2021 International Residential Code, Chapter 40 — E4001.6 switch height, E4002.14 tamper-resistant receptacles — Switch handle no higher than 6 ft 7 in; no general mounting height for receptacles.
- NFPA 70, National Electrical Code — The model code behind the IRC electrical chapters (receptacle spacing in 210.52).
- 2010 ADA Standards for Accessible Design — 308.2.1 and 308.3.1 reach ranges — Operable parts 15 in minimum, 48 in maximum above the floor.
- DIN 18015-3:2016-09 Elektrische Anlagen in Wohngebäuden — Teil 3: Leitungsführung und Anordnung der Betriebsmittel — The German standard for installation zones and device positions in homes (the full text is sold by DIN Media).
- Baunetz Wissen — Leitungsverlegung und Installationszonen — Summary of DIN 18015-3:2016-09: zones 15–45 cm below the ceiling, 100–130 cm and 15–45 cm above the floor, 10–30 cm beside doors, windows and corners; preferred heights 105 cm and 30 cm.
Start designing your room
Put this into practice in the floor planner: draw it, furnish it, walk through it in 3D — on web, iOS, and Android.
Open RoomSketch3DOne-time purchase · No subscription · Web, iOS & Android