Floor plan symbols
Every standard floor-plan symbol, by trade. The reference for reading a plan.
Floor plans use standardized symbols for trades — electrical, plumbing, HVAC. These conventions vary slightly by region and standard (US AIA, IEC, etc.) but the core set is universal.
The list below is a general reference for reading any plan — not every symbol in it is built into RoomSketch3D. The last section lists exactly what the app includes.
Symbols exist because a plan drawn at ¼″ = 1′ can't show a real outlet: a 2¾″-wide receptacle would be a speck. So each trade agrees on a small, simple mark that stands for the device, with a letter or a subscript for the variant (GFCI, S₃, WP). The mark shows what the device is and where it goes along a wall; its height usually lives in a note, a legend or an elevation drawing, not in the symbol. Every set of drawings that uses symbols should carry a legend that says what each one means — when a symbol on someone else's plan doesn't match this page, the legend on that plan wins.
The screenshots on this page are real RoomSketch3D plans: the kitchen and living room of the Medium 2-Bedroom Apartment template with an electrical plan added (GFCI, range and single outlets, a stacked switch and outlet with their heights, a dimmer pair, lights wired with circuit lines), a bathroom and utility space with plumbing and HVAC symbols, a living room with low-voltage devices, and a European room drawn with the European symbol set.
In this guide
- 1
Electrical — outlets
Duplex outlet: ⊕ (circle with two slots) — standard wall outlet. Quad outlet: Two duplex outlets stacked. GFCI outlet: Outlet with 'GFCI' label — required in bathrooms, kitchens, outdoor. 220V outlet: Larger circle, often labelled '220' — for stoves, dryers. Floor outlet: Circle with rectangle around it — outlet in the floor. How to read them: an outlet symbol is drawn on the inside face of the wall it is mounted on, so you can tell which room it serves even on a thin interior wall. Letters beside the symbol give the type: GFCI (ground-fault protected, for wet areas), WP (weatherproof), R (range), USB, TR (tamper-resistant), 240V or 220 (a heavy appliance circuit). A symbol with no letter is an ordinary duplex receptacle. In the kitchen below, the outlet over the counter is tagged GFCI (and named Breaker 14), the range outlet behind the cooktop is tagged R, and the plain one by the fridge is a single receptacle. On the side wall a switch and an outlet are stacked at one spot, so each shows its height from the floor: 46" and 12".
Kitchen of the Medium 2-Bedroom Apartment: GFCI over the counter, R for the range, a stacked switch over an outlet with heights, a single + dimmer (D) pair by the door, and Breaker 5 to the lights. - 2
Electrical — switches
Single-pole switch: 'S' — one switch, one fixture. Three-way switch: 'S₃' — two switches control one fixture (top and bottom of stairs). Four-way switch: 'S₄' — three switches control one fixture. Dimmer: 'S_D' or 'S_DM'. Smart switch: 'S_W' (Wi-Fi). How to read them: the switch symbol sits on the wall beside the door, on the latch side, where your hand finds it when you walk in. A dashed or curved line from the switch to a light (a circuit line, sometimes called a switch leg) tells you which fixture it controls. Two S₃ switches joined to the same light mean you can turn it on at either end of a room or a stair; add an S₄ between them for a third location. On the plan, RoomSketch3D draws a US switch as a circled S with its letter beside it (3 for three-way, D for dimmer), and a European switch as a small circle with a slanted stroke.
- 3
Electrical — fixtures
Ceiling light: Circle with X. Recessed light: Circle with dot. Wall sconce: Half circle on the wall. Ceiling fan: Circle with curved lines. Pendant light: Circle with chain symbol above. Smoke detector: Circle with 'SD'. Junction box: Circle with 'J' or 'JB'. Breaker panel: Rectangle labelled 'PANEL' or 'EP'. How to read them: ceiling fixtures are drawn where they sit on the ceiling, so they appear in the middle of the room on top of the furniture — they are not on the floor. Smoke and CO detectors are usually tagged SD, CO or SD/CO. A low-voltage set (data jack, Wi-Fi access point, doorbell, camera, motion sensor) often uses small squares or triangles with its own letters; check the plan's legend for those, because they vary more between offices than power symbols do.
Living room: a ceiling fan on a 4-way switch (4), smart (S + Wi-Fi) and occupancy (OS) switches by the door, Wi-Fi, CCTV, a track light, a doorbell and a smoke/CO detector. - 4
Plumbing
Sink: Rectangle or oval with faucet symbol. Toilet: Oval (bowl) + rectangle (tank). Tub: Rectangle, often labelled. Shower: Rectangle with X or 'SH'. Water heater: Circle or rectangle labelled 'WH'. Hose bib: Circle with 'HB'. Floor drain: Circle with cross or 'FD'. Shut-off valve: Circle with 'V' or specific valve symbol. How to read them: fixtures (toilet, sink, tub, shower) are drawn at their real size from above, so you can measure them like furniture. The small symbols are the parts you can't see in a finished room: the shut-off valve (a bow-tie between two lines), the floor drain, the hose bib on an outside wall and the water heater. On a remodel, these tell a plumber where water already arrives and leaves, which is usually the cheapest place to keep the fixtures.
Plumbing and HVAC in a 11 × 10 ft bath/utility room: water heater (WH), shut-off valve, floor drain, hose bib, a supply vent (diagonal hatching), a return vent (horizontal bars) and the thermostat (T). - 5
HVAC
Supply vent (ceiling): Square with X or arrow. Return vent: Rectangle with horizontal lines. Thermostat: Circle with 'T' or 'TH'. Floor register: Rectangle in floor. Wall register: Rectangle on wall. How to read them: supply vents blow conditioned air in and are usually spread around the outside of a room, often under windows; return vents pull air back to the furnace and are larger and fewer, often in a hall or central wall. Keep both clear when you place furniture: a sofa over a floor register or a bookcase in front of a return makes the room harder to heat and cool. The thermostat goes on an interior wall, away from windows, sun and supply vents, so it reads the room and not a draft.
- 6
Other
North arrow: Arrow with 'N'. Door swing: Quarter-circle arc. Window: Two parallel lines (in wall plane). Stairs: Multiple parallel lines with arrow showing 'UP' or 'DN' direction. Dimension line: Line with arrows at both ends and a measurement label. These are the drawing conventions every plan shares, whatever the trades. See how to read a floor plan for how walls, doors, windows and dimensions read, and floor planning glossary for the vocabulary.
- 7
European symbols
Plans drawn in Europe (and much of the world outside North America) use the installation symbols of the IEC family of standards rather than the US set. The look is different, the meaning is the same:
Device US plan European plan Socket / outlet Circle with two slots or two parallel strokes Half-circle (cup) on a short stem from the wall Earthed socket (all US duplex outlets are grounded) Cup with a line across the opening Double / triple socket Quad outlet or labelled count Cup with a small 2 or 3 Outdoor socket WP IP44 (the ingress-protection rating) Switch S with subscript Small circle with a slanted stroke; extra strokes for 2-gang, a reversed tick for two-way 400 V / three-phase 240V / 220 Cup with 400V In RoomSketch3D you pick the set in the Symbols panel: US, Europe or All.
The Europe pack: eight sockets along the bottom wall (unearthed, earthed, 2, 3, switched, IP44, USB, 400V) and six switches along the top (one-way, 2-gang, two-way, intermediate, dimmer, push button). - 8
Combinations and circuit line styles
Two more conventions you will meet on installation plans, especially European ones: Combinations (multi-gang boxes). Several devices in one frame (a switch with a socket below it, a double or triple socket, two or three switches by a door) are drawn as each device's own symbol, grouped by a thin frame. Side-by-side devices sit along the wall inside the frame; devices stacked one above the other are often drawn as separate symbols outward from the wall, each with its height from the floor written beside it (German installation plans often write 105 and 30, in cm), because a plan view can't show height otherwise. RoomSketch3D draws them exactly that way: side by side in a thin frame, stacked without a frame and with each device's height beside it (whole cm on a metric plan, inches on an imperial one). See outlet and switch combinations. Circuit lines. A dashed line from a switch to a light is the classic US switch leg; installation plans often route lines along walls with right-angle bends, and some offices use solid lines for home runs to the panel. In RoomSketch3D a circuit line can be dashed or solid, one of six preset colours or any colour you pick, routed with bends, and named after its breaker; the export's circuit table shows each line's colour and style next to its name.
Stacked pairs show their heights; side-by-side groups sit in a thin frame (US left, European right). - 9
In RoomSketch3D
Symbols have their own Symbols panel (the Symbols button in the editor; in the full catalog they're under the Symbols tab). It has about 70 built-in symbols, sorted into US, Europe and Shared packs (All shows every pack): US (27): outlets — Single, Duplex, Quad, GFCI, 240V, 20A, Tamper-Resistant, Isolated Ground, AFCI, Range, Dryer, Weatherproof, Switched, USB and Floor Outlet; switches — Single, Double, 3-Way, 4-Way, Dimmer, Smart, Pilot Light, Key, Timer, Occupancy Sensor, Weatherproof and Low Voltage. Europe (14): sockets — Earthed, Unearthed, Double, Triple, Switched, Outdoor IP44, USB and 400V 3-Phase; switches — One-Way, 2-Gang, Two-Way, Intermediate, Dimmer (EU) and Push Button. Shared (28): lights (Ceiling, Recessed, Wall, Pendant, Track, Under-Cabinet), Ceiling Fan, Electrical Panel, Smoke, CO and Smoke/CO Detectors, Doorbell, Motion Sensor, Junction Box; plumbing — Shut-off Valve, Floor Drain, Hose Bib, Water Heater; HVAC — Thermostat, Supply Vent, Return Vent; telecom — Phone Jack, Data Jack, Wi-Fi Access Point; CCTV Camera; and North Arrow, Marker Dot and Callout Circle. Each outlet and switch type draws its own standard plan symbol (a GFCI outlet is tagged GFCI, a dimmer S with a D, and so on). Circuit line in the Symbols panel joins switches, outlets and lights into a circuit (see circuit lines), and the export's Symbol legend & circuit table option (ticked by the Electrical plan view) adds a Symbol legend listing each type used, with a count, plus a Circuits table — see electrical plan outlets switches symbols. Outlet and switch symbols are drawn at plan size (about what a 1:50 installation plan uses), so they shrink and grow with the walls as you zoom. Anything else from the general reference above can be added with Upload custom symbol (a transparent PNG kept in your library for every plan — see upload custom symbols). Symbols appear on the 2D plan and in every export and print; free-standing symbols such as lights and vents do not appear in the 3D view. The panel opens on the pack that matches your measurement units (US for feet and inches, Europe for metres) and remembers the one you pick last. Outlets and switches are tap-a-wall tools: pick one, tap a wall, and it sits on that wall at a standard height — a duplex outlet 12″ above the floor, a GFCI 42″ (above a counter), a switch 46″. Lights, vents, detectors and jacks drop into the room like furniture and can be dragged anywhere; the Wall Light, Under-Cabinet Light and Doorbell are placed by tapping a wall and stay on it. Select a placed outlet or switch to change its kind or its Mount height (the bottom of the plate), or to add more devices at the same spot as a combination. Outlets, switches and the Floor Outlet also show in the 3D view.
Symbols panel → US: outlet and switch tiles with their real sizes, plus Upload custom symbol and Circuit line. - 10
The symbol legend on an electrical plan
A plan full of symbols needs a key. Export with Export / Print / Share → PNG/JPG/PDF or Print, tick Symbol legend & circuit table under Options (the Electrical plan view under Views ticks it for you), and RoomSketch3D adds a Symbol legend under the drawing: one row per symbol type used, with its mark and a count (Outlet (Duplex) ×5, Recessed Light ×2), then a Circuits table naming each circuit line and what is on it (Breaker 5 — Switch (Single), Recessed Light ×2, Pendant Light ×2). That is what an electrician needs to quote the job: how many of each device, and which switch runs which lights. The footer gives the plan's overall size, its gross and usable area and the date.
The exported legend: each symbol with a count, and each circuit with its colour, style and devices.
Tips
Read the legend first
Offices and countries differ in the small details (a dimmer can be S_D, S_DM or a D beside the S). Before you count outlets on someone else's plan, find its legend; RoomSketch3D's Symbol legend & circuit table option prints one for the symbols you used.
Put the switch on the latch side
Place switches on the wall next to the door's handle side, not behind the hinge, so the door never hides the switch when it swings open. Flip a door's hinge side and check the switch is still reachable.
Draw circuits, not just devices
A plan with 20 outlets and no circuit lines tells an electrician where things go but not how they are switched. Use Circuit line to join each switch to the lights it controls; the export lists every circuit by name.
Show symbols only when you need them
View & Layers → Show outlets, switches & symbols hides every symbol on the plan while you arrange furniture and brings them back for the electrical pass.
Common confusions
Reading a ceiling symbol as a floor item
A circle-with-X in the middle of a bed is a ceiling light above it, not something on the mattress. Ceiling fixtures, detectors and supply vents are drawn on top of whatever is below them.
Mixing US and European sets on one plan
A US duplex and a European earthed socket look nothing alike; using both confuses the person who builds it. Pick one pack for the plan and stick to it.
Treating a symbol as a code check
A GFCI tag shows the intent, not that the circuit meets your local electrical code. The electrician and the local inspector decide what protection each outlet needs.
Frequently asked questions
What is the symbol for a GFCI outlet on a floor plan?
The normal outlet symbol with GFCI written beside it (or inside it). RoomSketch3D's Outlet (GFCI) draws exactly that and places it 42″ above the floor by default, the usual height over a kitchen counter.
What does S₃ mean on a floor plan?
A three-way switch: one of a pair that both control the same light, such as at the top and bottom of a stair. S₄ is a four-way switch, used between two three-ways for a third location.
How do I show which switch controls which light?
Draw a circuit line from the switch to each light. In RoomSketch3D use Circuit line in the Symbols panel; each circuit gets a name and any colour, and the export's circuit table lists it.
Can I use European symbols?
Yes. In the Symbols panel choose Europe for sockets and switches drawn the European way (earthed, double, triple, IP44, 400V and USB sockets; one-way, 2-gang, two-way, intermediate, dimmer and push-button switches).
Why don't I see lights or vents in 3D?
Free-standing symbols such as lights, vents and detectors are 2D plan symbols; they show on the plan and in every export and print, but not in the 3D view.
How is a switch with a socket below it drawn on a plan?
As two symbols at one spot, the second drawn out from the wall because a plan can't show height, usually with each height written beside it. In RoomSketch3D, drag the socket onto the switch or tap Add outlet on the switch and choose Stacked: both symbols draw without a frame, each with its height from the floor; see outlet and switch combinations.
What is the difference between a solid and a dashed circuit line?
It depends on the office: dashed lines usually mark switch legs and branch circuits, solid lines home runs. The plan's legend should say. In RoomSketch3D you pick Solid or Dashed per line, and the export's circuit table shows each style next to the circuit name.
A symbol I need isn't in the list. What can I do?
Use Upload custom symbol in the Symbols panel: upload a transparent PNG and it stays in My Library for all your plans. See upload custom symbols.
Start designing your room
Draw it, furnish it, walk through it in 3D — on web, iOS, and Android.
Open RoomSketch3DOne-time purchase · No subscription · Web, iOS & Android