Door clearance: swing arcs and approach space
Every door reserves floor: the arc a hinged door sweeps, room beside the handle, and a clear approach in front. Here's how much, where the numbers come from, and how RoomSketch3D checks it.
A door doesn't just occupy the wall it's in. It reserves floor around it: the swing arc for a hinged door, room beside the handle to stand and pull, and a clear approach in front of any door. Furniture in those zones is the most common layout mistake, because on paper the room looks fine until the door hits the cabinet.
Quick answer. A hinged door needs a clear quarter circle with a radius equal to its width (a 32 in door: about 5½ sq ft of floor). Keep about 18 in clear beside the handle on the pull side and about 36 in clear in front of every door. Hallways are at least 36 in wide (IRC R311.6), plus the door's width where a door swings into them.
In this guide
- 1
Hinged door swing arc
Radius = door width. A 32 in door sweeps a quarter circle 32 in in radius; a 36 in door, 36 in. A French pair needs two arcs, each the width of one leaf, so a 6 ft pair sweeps two 36 in quarter circles side by side. On a 3- or 4-panel French door only the leaves that open sweep an arc (the centre leaf, or the middle pair); the fixed sidelites at the ends don't. Nothing that stands on the floor can be inside the arc: furniture, a vanity, a toilet, a rug thick enough to catch the door. In RoomSketch3D, Smart Flow Check outlines anything inside an open door's arc in red and lists it: Base Cabinet 30" blocks door — Move it away from the door swing. It tests the side the arc is drawn on, so on an inside wall the In / Out setting decides which room is checked.
A 6′ French door: the left leaf's 36″ arc hits the base cabinet, so Flow Check marks it red. - 2
What Flow Check tells you
Tap the Flow check button at the top left to see the list. A red entry (blocks door) is an issue to fix: move the piece, flip the door's hinge side or swing (L / R, In / Out), or use a door without an arc. Tap the entry to select the piece.
The red issue: the cabinet is in the door's swing. - 3
Sliding doors
No swing arc, so the same 6 ft opening as a sliding glass door frees the floor the French leaves needed. It still needs a clear approach: about 36 in of floor in front of the door. Flow Check gives an orange warning (crowds the sliding glass door — Leave at least 36" of clear approach space in front) for anything standing in that strip. Also keep tall furniture off the stretch of wall the moving panel slides along on the inside, so it opens fully; Flow Check doesn't check that.
Same opening as a slider: no arc, so the cabinet no longer blocks it; it's only within the 36″ approach (orange). - 4
Warnings vs issues
Orange is a warning: the door works, but the approach is tight. Red is an issue: the door can't open fully. Fix the reds; decide on the oranges (a cabinet beside a slider is often fine; a sofa in front of it isn't).
The orange warning: the cabinet crowds the slider's approach. - 5
Pocket and barn doors
No swing arc. A pocket door disappears into the wall; a barn door slides along its face. Approach: the same clear floor in front as any door. Barn doors: the wall the door parks against (about one door width beside the opening) can't have anything on it: no shelves, thermostats, light switches or frames. Pocket doors: nothing fixed into the wall over the pocket. Flow Check doesn't check either, so look at the wall beside the opening yourself.
- 6
Latch side and approach (accessibility)
To pull a door open you stand beside the handle, out of the door's way. The ADA 2010 Standards set the minimum for a door approached head-on from the pull side: 60 in of clear floor in front of the door and 18 in beyond the latch edge (404.2.4); the push side needs less. Two doors in a row need 48 in plus the width of any door swinging into the space between them (404.2.6). These are accessibility minimums that apply to public buildings and accessible homes; for any home, 18 in beside the handle and a clear approach make a door easy to use.
- 7
Hallways and doors that swing into them
The residential code's minimum hallway is 36 in wide (IRC R311.6). A door that swings into a hallway takes its own width out of it while it's open, so an outswinging 32 in door in a 36 in hall blocks it completely. Swing doors into the rooms, or make the hall wider. Exterior doors need a landing at least as wide as the door and 36 in deep in the direction of travel (IRC R311.3).
- 8
The fix: clear floor and a green Flow Check
Back as the original 3 ft swing door, the single 36 in arc stops short of the cabinet, the sofa is outside it, and Flow Check shows OK. The 6 ft French door failed only because its left leaf reached the cabinet; a narrower pair, a slider or moving the cabinet one cabinet-width along would also fix it. Switching between door kinds to test this takes one tap on the type chip; see change a door type.
A 3′ swing door whose arc misses the cabinet and the sofa: nothing flagged.
Tips
Keep pieces a door-width away from the door's wall
A typical interior door is 30–32 in wide. Anything within that distance of the door's wall, on the swing side, near the door, is probably in the arc.
Hallway off a door = 36 in plus the door's width
If a 32 in door swings into a hallway, the hall needs about 68 in for someone to pass while it's open. Otherwise swing the door into the room.
Try another kind of door
When an arc won't clear, a pocket, barn or sliding door of the same width frees the floor. Switch it in place with the type chip and let Flow Check re-check.
An inside doorway needs clear floor on both sides
You walk through a bedroom door from the hall and from the bedroom, so leave about 36 in clear in front of it in both. Flow Check checks both sides of any door, French door, sliding door, doorway or opening in an inside wall, and gives the orange … crowds the door warning for a piece on either side. A door in an outside wall is checked on the inside only; check the porch or landing yourself.
Common confusions
Furniture beside the handle
Even with the arc clear, a bookcase right against the latch side means you can't stand to pull the door. Leave about 18 in.
Planning with doors set to Closed
A Closed door has no arc, so Flow Check can't check its swing. Leave doors Open while you arrange furniture.
Clearing only the room you're furnishing
It's easy to arrange a bedroom so its own side of the door is clear and forget the hall side, where a console or a bookcase ends up right in front of the door. Both sides of an inside door need about 36 in. Flow Check warns about either side, so look at the whole list, not just the room you're working on.
Frequently asked questions
How much clearance does a door need?
A hinged door: a clear quarter circle with a radius equal to its width (32 in for a 32 in door), plus about 18 in beside the handle on the pull side. Any door: about 36 in of clear floor in front. Sliding, pocket and barn doors have no arc.
What's the minimum hallway width?
36 in in a house (IRC R311.6). Add the door's width where a door swings into the hall.
How much space do you need between two doors?
For accessible design, 48 in plus the width of any door swinging into the space between two doors in a row (ADA 404.2.6). In a house, at least make sure the two arcs don't overlap.
Does Smart Flow Check enforce door clearance?
Yes. It flags furniture in the swing arc of open hinged and French doors in red (blocks door), and furniture in the 36 in in front of doors, sliding doors and openings in orange (crowds …). The approach is checked on both sides of a doorway in an inside wall and on the inside of one in an outside wall; a raised pass-through has none. Set the swing direction correctly so it checks the right side, and leave doors Open while you plan. Pocket and barn doors have no arc and no approach check, so clear the floor in front of them yourself.
Does Flow Check check the hallway side of a bedroom door?
Yes. A door in an inside wall is walked through from both rooms, so Flow Check checks the 36 in in front of it on both sides and warns (… crowds the door) when anything stands in either strip. The swing arc is checked on the side the door is drawn opening into. On an inside wall, only a plain (one-sided) fireplace gets its approach on one side, and a raised pass-through gets none, since nobody walks through it.
Sources
- 2010 ADA Standards for Accessible Design, 404.2.4 and 404.2.6 — Pull-side front approach: 60 in perpendicular, 18 in beyond the latch; doors in series: 48 in plus the width of doors swinging into the space.
- International Residential Code (IRC) 2021, R311.3 — landings; R311.6 — hallways — Hallways at least 3 ft wide; exterior door landings at least as wide as the door and 36 in deep.
Start designing your room
Put this into practice in the floor plan maker: draw it, furnish it, walk through it in 3D — on web, iOS, and Android.
Open RoomSketch3DOne-time purchase · No subscription · Web, iOS & Android